Skip to main content

Aparna RMC

lightweight concrete in bangalore

Lightweight concrete is concrete made deliberately lighter — roughly 300 to 1,840 kg/m³ against 2,300–2,400 kg/m³ for normal concrete — by using lightweight aggregate or by introducing stable air into the mix. It is mainly used for terrace insulation, sunken slab filling, floor levelling, void filling, and other applications where reducing dead load is important.

What Lightweight Concrete Means on a Bangalore Site?

On building sites, terms such as lightweight concrete, foam concrete, cellular lightweight concrete, and CLC are often used for similar cast-in-situ materials. The exact mix and density can vary depending on the application.

AAC is different because it is a factory-made masonry block, and not a ready-mix material. The density selected for lightweight concrete also affects where it can be used.

Density Bands and What Each One Is For

Density bandTypical descriptionSuited toTypical application
600–1,000 kg/m³Lower-density lightweight concreteThermal insulation and load reductionTerrace insulation and roof-slope screeds
600–1,200 kg/m³Lightweight filling concreteFilling applications where reducing dead load is importantSunken slab filling and void filling
1,000–1,400 kg/m³Medium-density lightweight concreteLevelling and lightweight build-upsFloor levelling
1,200–1,850 kg/m³Higher-density lightweight concreteHigher-density build-ups, subject to project requirementsRooftop amenity build-ups
800–1,850 kg/m³EchelonCrete rangeApplications selected according to required density and performanceStandard EchelonCrete density range

EchelonCrete by Aparna RMC has a standard density range of 800–1,850 kg/m³. The technical team selects the required density according to the application and project requirements. Lower-density mixes can be used where insulation and dead-load reduction are important, while higher-density mixes can be selected for applications requiring greater strength.

Where Lightweight Concrete Is Used in Bangalore Buildings?

Lightweight concrete is mainly selected where a project needs a lighter fill or levelling layer without using conventional heavy materials. The required density depends on the application and site conditions.

Terrace and Roof Insulation Screed

A lower-density EchelonCrete mix in the range of 600–1,000 kg/m³ can be considered for terrace insulation and roof-slope screeds. Lower density can help reduce the added dead load and improve thermal insulation. The required slope, thickness and final density should be selected according to the roof build-up and project requirements.

Sunken Slab and Bathroom Filling

Sunken slabs often need filling material to create the required floor level and accommodate services. EchelonCrete in the 600–1,200 kg/m³ range can be considered to replace heavier filling materials such as cinder or brickbats and reduce the additional dead load.

Waterproofing and drainage requirements should be completed in the correct sequence before the lightweight fill is placed. The final density should be selected based on the project details.

Floor Screeds and Levelling

EchelonCrete in the 1,000–1,400 kg/m³ range can be considered for floor levelling where a build-up layer is required over an existing slab. This range can provide a balance between strength and reduced weight, depending on the project requirements.

It can be useful in fit-outs, renovations and areas where floor levels need to be adjusted. The final density and surface requirements should be confirmed for the project.

Void Filling, Trenches and Backfill

EchelonCrete in the 600–1,200 kg/m³ range can be considered for void filling and other suitable fill applications. Lightweight concrete can provide a continuous fill while adding less dead load than heavier conventional filling materials.

The choice between lightweight concrete and conventional backfill depends on the space, required density, access and final use of the filled area.

Rooftop Amenity Build-Ups

For rooftop amenity build-ups such as gardens and pergolas, EchelonCrete in the 1,200–1,850 kg/m³ range can be considered where the required strength and project design permit. The selected density should account for the additional load from the complete rooftop build-up.

The required mix should be selected according to the application and structural requirements and should not be treated as a substitute for a structural concrete grade without project-specific approval.

Is Lightweight Concrete Structural? What It Should Not Be Used For

Lightweight concrete is commonly used for fills, screeds and levelling layers over an existing structural slab. The suitability of a particular density and mix depends on the application and project requirements.

It should not be selected for:

  • Structural slabs without structural design approval
  • Beams and columns
  • Foundations
  • Any element carrying design loads unless specifically designed and approved for that use

Where a project requires conventional structural concrete, the required structural grade should be specified based on the design and applicable standards.

Lightweight Concrete, AAC Blocks or Normal Concrete?

The three materials serve different purposes. The right choice depends on whether the project needs a poured material, masonry units or conventional structural concrete.

FeatureCast-in-situ lightweight concreteAACNormal concrete
Supplied asReady-mixed and poured on siteFactory-made masonry unitsReady-mixed and poured on site
Typical useScreeds, fills, levelling and insulation layersWalls and partitionsStructural elements
Fills irregular spacesYesNo, laid in coursesYes, with suitable placement
Carries design loadGenerally noNo, for non-load-bearing wallsYes, when designed for structural use
Available from a ready-mix plantYesNoYes

Note: Aparna RMC supplies lightweight concrete and normal concrete but not AAC.

What Affects the Cost of Lightweight Concrete in Bangalore?

The cost of lightweight concrete depends on the project rather than one fixed rate. Key factors include:

  • Required density and mix specification
  • Total volume and pour size
  • Pumping requirements and site access
  • Distance from the supplying plant
  • Scheduling and pour requirements
  • Thickness of the lightweight layer
  • Site conditions and placement requirements

It may be quoted by cubic metre or, for some applications, calculated based on the area and required thickness. A project-specific quotation is therefore more useful than a general market rate.

Ordering and Placing It on Site

Lightweight concrete should be ordered based on the application, required density, quantity and site conditions. Discuss the pour with the plant team in advance, as specialised materials and production planning may be required.

Before ordering, confirm:

  • Required density and application
  • Quantity and pour date
  • Pumping requirement
  • Site access
  • Placement area and levels
  • Site preparation requirements
  • Whether specialised ingredients or production planning are required

Large or continuous EchelonCrete pours should be scheduled with the plant team in advance. Supply depends on plant logistics and specialised ingredient availability, while larger pours can be coordinated across nearby plants where conditions allow.

EchelonCrete can be pumped when the appropriate mix, equipment and pipeline arrangement are used. Pumping performance depends on the mix design, pump type, pipeline configuration, placement conditions and site requirements. The suitable pumping arrangement should be confirmed with Aparna RMC before placing the order.

Curing should be carried out according to the specified application, mix, thickness and site conditions. Proper curing helps the placed material develop the required performance and reduces the risk of premature drying and cracking.

Lightweight Concrete Supply Across Bangalore

Aparna RMC supplies lightweight ready-mix concrete as EchelonCrete for project-specific applications. Supply planning depends on the required mix, quantity, application and plant availability.

Aparna RMC plant locations in Bangalore include:

  • Anjanapura
  • Sarjapura
  • Budigere
  • Devanahalli
  • Vidyanagar
  • Electronic City

Plant availability and the suitable supplying location should be confirmed when placing an order. Service areas can also vary depending on the project and delivery requirements.

Aparna RMC has an expansive network of 36 automated batching plants. Larger EchelonCrete pours can be coordinated across nearby plants where plant logistics and specialised ingredient availability allow.

Indian Standards That Apply

The relevant standards depend on the material and its application.

Standard / certificationRelevance
IS 9142 Part 1 & Part 2Specifications and testing criteria for lightweight aggregates used in concrete, depending on aggregate type
IS 2185 (Part 3)Autoclaved cellular aerated concrete blocks
IS 2185 (Part 4)Preformed foam cellular concrete blocks
IS 456:2000Relevant provisions for the use of lightweight aggregates in concrete, including Clause 5.3.2.
IS 4926Requirements related to ready-mixed concrete production and quality control
IS 10262Guidelines for concrete mix proportioning
ISO 9001:2015Aparna RMC production and supply-chain workflow; scope stated as design, manufacture and supply of ready-mix concrete and specialty concrete mixes
ACI 213RGuide for structural lightweight aggregate concrete

These standards cover different parts of lightweight concrete materials, ready-mixed concrete production, mix proportioning, and structural concrete practice. Cast-in-situ EchelonCrete should be specified according to its required density, application, and project requirements.

Need lightweight concrete for your project? Share your application, required quantity, and project location with Aparna RMC to discuss the suitable mix and supply requirements.

Frequently Asked Questions

Lightweight concrete can also be called foam concrete, cellular lightweight concrete, or CLC, depending on how it is produced. These terms refer to lightweight poured materials. But AAC is different because it is produced as factory-made blocks and is not supplied as ready-mix concrete.

EchelonCrete has a standard density range of 800–1,850 kg/m³, while specific applications may use lower-density ranges depending on the engineered mix. Terrace insulation and roof-slope screeds may use 600–1,000 kg/m³; sunken slab and void filling 600–1,200 kg/m³; floor levelling 1,000–1,400 kg/m³; and rooftop amenity build-ups 1,200–1,850 kg/m³, subject to project requirements.

Foam concrete is commonly used for terrace and roof insulation screeds, sunken slab filling, floor levelling, and void filling. It can also be used in some selected non-structural applications. The density and mix should be selected as per the required application and site conditions.

Foam concrete generally has lower strength than conventional structural concrete, so it is not suitable for load-bearing elements unless specifically designed for that purpose. It also needs a suitable substrate and proper placement. The thickness and required density can affect the quantity and project cost.

Sunken slabs can be filled using different materials depending on the project. These may include conventional filling materials or poured lightweight fill. Lightweight concrete can provide a continuous fill and reduce the additional dead load compared with heavier materials. Waterproofing and drainage should be completed as required before filling.

Yes, AAC blocks are lightweight masonry units. But AAC blocks are different from cast-in-situ lightweight concrete. AAC is manufactured in a factory and supplied as blocks, while ready-mix lightweight concrete is transported to the site and poured into the required area.

There is no single rate for foam concrete. The cost depends on density, quantity, mix requirements, pumping, site access, plant location and project conditions. It may be calculated by cubic metre or based on the area and thickness required. A project-specific quotation is therefore needed.

Aparna RMC supplies lightweight ready-mix concrete as EchelonCrete for project-specific applications. Supply and plant availability should be confirmed based on the project location, required quantity, application, and scheduling requirements.

For standard low-density insulation mixes, the engineer has indicated a typical thermal conductivity range of 0.15–0.40 W/m·K. The actual value varies with the engineered dry density and mix composition, so project-specific technical documentation should be confirmed where a tested value is required.